Tennis Court Lighting Photometric Data

home > athletic, tennis court & stadium lighting > tennis court lighting  « back

Single Recreational & Residential Court 
(Court 1)

Lumen Rating  107,800
Initial Foot candle levels at 3-foot above court
Fixtures are mounted at 22' above court

    Summary          Click here for Definitions
    Average    62.79
    Maximum  76.3
    Minimum   46.3
    Avg/Min Ratio   1.36
    Max/Min Ratio  1.65


Click here to view 3-D Photometric Illustration
Dual Recreational & Residential Court 
(Court 2)

Lumen Rating  107,800
Initial Foot candle levels at 3-foot above court
Fixtures are mounted at 22' above court

    Summary          Click here for Definitions
    Average    65.81
    Maximum  102
    Minimum   46.3
    Avg/Min Ratio   1.42
    Max/Min Ratio  2.20


Click here to view 3-D Photometric Illustration

Single Tournament & Club Court 
(Court 3)

Lumen Rating  107,800
Initial Foot candle levels at 3-foot above court
Fixtures are mounted at 22' above court

    Summary          Click here for Definitions
    Average    72.1
    Maximum  79.4
    Minimum   61.1
    Avg/Min Ratio   1.18
    Max/Min Ratio  1.30


Click here to view 3-D Photometric Illustration
Dual Tournament & Club Court
(Court 4)

Lumen Rating  107,800
Initial Foot candle levels at 3-foot above court
Fixtures are mounted at 22' above court

    Summary          Click here for Definitions
    Average    74.73
    Maximum  99.8
    Minimum   59.4
    Avg/Min Ratio   1.26
    Max/Min Ratio  1.68


Click here to view 3-D Photometric Illustration

Dual Narrow Recreational & Residential Court (Court 5)

Lumen Rating  107,800
Initial Foot candle levels at 3-foot above court
Fixtures are mounted at 22' above court

    Summary          Click here for Definitions
    Average    66.95
    Maximum  109
    Minimum   41.1
    Avg/Min Ratio   1.63
    Max/Min Ratio  2.65


Click here to view 3-D Photometric Illustration
Dual Narrow Tournament & Club Court 
(Court 6)


Lumen Rating  107,800
Initial Foot candle levels at 3-foot above court
Fixtures are mounted at 22' above court

    Summary          Click here for Definitions
    Average    74.22
    Maximum  111
    Minimum   49.9
    Avg/Min Ratio   1.49
    Max/Min Ratio  2.22


Click here to view 3-D Photometric Illustration

Lumen Rating: the unit of measurement used to indicate the quantity or intensity of any lamp.  Think of it in terms of the lamps raw power.  Lumens are measured at the lamp.  Lumens are used in the lumen method calculation to determine the number of fixtures necessary and their spacing to maintain a given foot candle level as prescribed by IES (Illuminating Engineering Society.)

Definitions

Recommended Illumination For Outdoor Tennis Facilities
Performance Criteria

Recommended

Minimal

Excellent Very Good Good Fair
Average Maintained Horizontal Foot candles within PPA 125 100-75 75-50 50-30
Minimum Maintained Horizontal Foot candles within PPA 100 100-60 60-40 40
Maximum Uniformity Ratio 1.50 1.70 2.00 2.50
Notes:
  1. Maintained horizontal foot candles is determined by applying a light loss factor (LLF) to the initial calculated or measured foot candles.  LLF is dependent upon lamp characteristics, fixture design, fixture maintenance, voltage variations and atmospheric conditions.  It normally varies between .6-.85. 
  2. Average maintained and minimum maintained horizontal foot candles should be calculated within the playing lines and/or within the Primary Playing Area (PPA) determined by the specifications of the project with foot candle values multiplied by the appropriate LLF.
  3. Uniformity ratio is defined as the ratio of maximum foot candles divided by the minimum foot candles.
  4. Primary Playing Area (PPA) is defined as the area that includes 6' beyond the sidelines and 10' behind the baseline.